Patented green operating mode achieves efficiencies over 97%. Smart-ups was the first network UPS to be Energy Star certified. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Dynamic battery replacement date indicator and automatic self tests insure battery reliability and warn in advance of needing replacement.

Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Designed and manufactured by APC for over 23 years, Smart-UPS is the world’s most trusted network UPS with over 25 million units sold.

. User Manual English ® APC Smart-UPS 1000/1500 VA 110/120/230 Vac Tower/Rack-Mount 2U Uninterruptible Power Supply 990-1851D 03/2007. Introduction The APC Uninterruptible Power Supply (UPS) is designed to prevent blackouts, brownouts, sags, and surges from reaching your equipment. The uninterruptible power supply (UPS) filters small util- ity line fluctuations and isolates your equipment from large disturbances by internally disconnecting from the utility line.

Tower Configuration Note: Illustrations in this document may appear different than the actual hardware. ' Mount the UPS in a Two-Post Rack ' Remove battery bracket screws, battery bracket, and battery. Note: For information on the four-post rack- mounting kit, see www.apc.com. & Reinstall battery, battery bracket, and screws. 2: S TART UP Connect Equipment to the UPS Rear Panels 110/120 V: 230 V: Note: A laser printer draws significantly more power than other types of equipment and may.

Apc Ups 750va

750va

overload the UPS. Connect the UPS to the Network (if Applicable) Network Connectors Serial Port Modem/Telephone/Fax. Start the UPS 1. Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords. 110/120 V models: The power cord is attached to the UPS.

The input plug is a NEMA 5- 15P. 230 V models: The power cord is supplied in the UPS literature kit. 3: O PERATION Front Display Panel 110/120 V 230 V NDICATOR ESCRIPTION On Line The UPS is supplying utility power to the connected equipment. On Battery The UPS is supplying battery power to the connected equipment.

Overload The connected loads are drawing more than the UPS power rating. Replace Battery/ The battery is disconnected or must be replaced.

APC Smart-UPS SUA750RM1U protects critical. APC Smart-UPS 750VA USB & Serial RM 1U 120V APC. Smart UPS signalling RS-232 cable, USB cable, User Manual.

4: U ONFIGURABLE TEMS ETTINGS ARE ADJUSTED THROUGH OWER HUTE SOFTWARE ACTORY ELECTABLE UNCTION ESCRIPTION EFAULT HOICES Self-Test Every 14 days Every 7 days Set the interval at which the UPS will (336 hours) (168 hours), execute a self-test. Every 14 days (336 hours), On Startup Only, No Self-Test. ETTINGS ARE ADJUSTED THROUGH OWER HUTE SOFTWARE ACTORY ELECTABLE UNCTION ESCRIPTION EFAULT HOICES Low Battery 2 minutes 2, 5, 7, 10 minutes The UPS will beep when 2 minutes of Warning battery runtime remains. PowerChute (Times are approxi- Business Edition mate.) Change the low battery warning inter- software provides. 5: S TORAGE AND AINTENANCE Storage Store the UPS covered in a cool, dry location, with the battery fully charged.

At -15 to +30 °C (+5 to +86 °F), charge the UPS battery every six months. At +30 to +45 °C (+86 to +113 °F), charge the UPS battery every three months. Battery Replacement The UPS battery life differs based on usage and environment. 6: T ROUBLESHOOTING HIPPING ERVICE Use the chart below to solve minor UPS installation and operation problems. Refer to www.apc.com with complex UPS problems. ROBLEM AND OSSIBLE OLUTION AUSE WILL NOT TURN ON UPS not connected to utility Check that the power cord from the UPS to the utility power supply is se- power supply. ROBLEM AND OSSIBLE OLUTION AUSE THE OVERLOAD LED IS ILLUMINATED AND THE EMITS A SUSTAINED ALARM TONE The UPS is overloaded.

The The connected equipment exceeds the specified “maximum load.” connected equipment is draw- The alarm remains on until the overload is removed. Disconnect nonessen- ing more VA than the UPS can tial equipment from the UPS to eliminate the overload. Shipping and Service Prepare the UPS for shipping: Shutdown and disconnect any equipment attached to the UPS. Shut down the UPS, and disconnect the UPS from the utility power outlet. Disconnect the battery. If the UPS requires service do not return it to the dealer.

Follow these steps: Review the problems discussed in Troubleshooting to eliminate common problems. 7: R EGULATORY AND ARRANTY NFORMATION 110/120 V models This equipment has been tested and found to comply with the limits for a Class A digital device, pur- suant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

Software hp printer. Limited Warranty American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must obtain a Returned Material Authorization (RMA) number from customer support.